Section |
Dimensions |
Mass |
Modulus of Section |
Moment of inertia |
||||
Width |
Height |
Thickness |
Thickness |
Per pile |
Wall |
|||
w |
h |
t |
s |
|
|
|
|
|
mm |
mm |
mm |
mm |
kg/m |
kg/m2 |
cm3/m |
cm4/m |
|
LARSSEN 408 |
400 |
200 |
10.5 |
7.8 |
48 |
120.1 |
874 |
8740 |
LARSSEN 413 |
400 |
250 |
13 |
8.9 |
60 |
149.9 |
1340 |
16800 |
LARSSEN 422 |
400 |
340 |
15.5 |
10.4 |
76.1 |
190.4 |
2270 |
38600 |
LARSSEN 607 |
600 |
309 |
7.4 |
7.3 |
49.4 |
82.3 |
754 |
11643 |
LARSSEN 608 |
600 |
310 |
8 |
7.8 |
52.2 |
87 |
810 |
12559 |
LARSSEN 609 |
600 |
312 |
9 |
8.5 |
56.8 |
94.7 |
904 |
14103 |
LARSSEN 610 |
600 |
330 |
8.4 |
7.1 |
55.3 |
92.1 |
1037 |
17103 |
LARSSEN 611 |
600 |
330 |
9 |
7.4 |
58.1 |
96.9 |
1100 |
18149 |
LARSSEN 612 |
600 |
330 |
10 |
8 |
62.9 |
104.8 |
1204 |
19872 |
LARSSEN 612C |
600 |
330 |
10 |
10 |
68.9 |
114.8 |
1269 |
20936 |
LARSSEN 613 |
600 |
409 |
8.4 |
7.7 |
61.3 |
102.1 |
1328 |
27191 |
LARSSEN 614 |
600 |
410 |
9 |
8 |
64.1 |
106.8 |
1408 |
28859 |
LARSSEN 615 |
600 |
411 |
10 |
8.5 |
68.8 |
114.6 |
1540 |
31639 |
LARSSEN 616 |
600 |
409 |
9.4 |
8.2 |
69.2 |
115.3 |
1605 |
32858 |
LARSSEN 617 |
600 |
410 |
10 |
8.4 |
72.1 |
120.1 |
1690 |
34645 |
LARSSEN 618 |
600 |
411 |
10.9 |
8.8 |
76.4 |
127.4 |
1817 |
37348 |
LARSSEN 618C |
600 |
360 |
13.4 |
9 |
81.6 |
136 |
1800 |
32400 |
LARSSEN 619 |
600 |
419 |
11.6 |
9 |
78.8 |
131.4 |
1920 |
40261 |
LARSSEN 620 |
600 |
420 |
12.2 |
9.2 |
81.6 |
136 |
2005 |
42105 |
LARSSEN 621C |
600 |
421 |
13.2 |
9.6 |
86.3 |
143.8 |
2146 |
45180 |
LARSSEN 621T |
600 |
411 |
13 |
8.7 |
82.2 |
137 |
2067 |
42480 |
LARSSEN 622T |
600 |
412 |
14 |
9.1 |
86.9 |
144.8 |
2206 |
45441 |
LARSSEN 623 |
600 |
430 |
14 |
9.4 |
89.5 |
149.2 |
2343 |
50376 |
LARSSEN 624 |
600 |
435 |
13.8 |
9.2 |
91.2 |
152 |
2424 |
52763 |
LARSSEN 625 |
600 |
436 |
14.4 |
9.4 |
94 |
156.7 |
2512 |
54771 |
LARSSEN 626 |
600 |
437 |
15.4 |
9.8 |
98.9 |
164.8 |
2660 |
58118 |
LARSSEN 627C |
600 |
420 |
18 |
11.8 |
106.2 |
177 |
2700 |
56700 |
LARSSEN 627 |
600 |
455 |
14.5 |
9.5 |
96.9 |
161.6 |
2701 |
61468 |
LARSSEN 628 |
600 |
456 |
15.3 |
9.8 |
100.8 |
168 |
2823 |
64375 |
LARSSEN 630 |
600 |
457 |
16.3 |
10.2 |
105.7 |
176.1 |
2976 |
68010 |
LARSSEN 631 |
600 |
451 |
18 |
10.3 |
109.1 |
181.9 |
3073 |
69300 |
LARSSEN 632 |
600 |
452 |
19 |
10.7 |
114 |
190 |
3200 |
72320 |
LARSSEN 633 |
600 |
453 |
19.8 |
11 |
117.7 |
196.2 |
3340 |
75618 |
LARSSEN 723 |
750 |
447 |
13 |
9.2 |
101.2 |
134.9 |
2254 |
50359 |
LARSSEN 725 |
750 |
450 |
14.6 |
10 |
110.4 |
147.2 |
2502 |
56301 |
U-Profile Spundwand Andere Klassifizierungen umfassen oszillierende oder nahezu oszillierende Wellen. Folglich wurden andere Materialquellen und alternative Transportmethoden als praktikabler eingestuft. Die meisten Reparaturarbeiten erfordern eine Entwässerung, um die Struktur freizulegen und einigermaßen trockene Bedingungen zu schaffen.
U-Profile Stahl Spundwand Schwerewellen werden weiter als Tiefwasser-, Übergangs- oder Flachwasserwellen klassifiziert. Die Nutzung dieser Brücken würde die Nutzung des vorhandenen lokalen Straßensystems erfordern, das geringere Belastungsgrenzen aufweist als für die Ausrüstung angenommen. In seiner einfachsten Form könnte dies bedeuten, einen Teil der Wehrkrone mit Sandsäcken abzudecken, um eine Reparatur durchzuführen.
Die Gesamtenergie eines Wellensystems ist die Summe seiner kinetischen Energie und seiner potentiellen Energie. Der Bau der Umleitungsdämme erfordert eine kontrollierte Platzierung, um den richtigen Querschnitt für die Flussumleitung und Erosionsvermeidung zu erreichen. Die Entwässerung kann auch Vorkehrungen für die Rettung von Fischen erfordern.