Section Dimensions sectional area Mass Moment of inertia Modulus of Section
Width Height Thickness Per pile Wall
W H t          
mm mm mm cm2/m kg/m kg/m2 cm4/m cm3/m
PU600 × 215 600 215.0 14.0 114.0 89.5 149.2 50376 2343
PU600 × 218 600 217.5 13.9 120.3 92.2 153.7 52420 2410
PU600 × 218 600 217.7 13.8 116.2 91.2 152.0 52763 2424
PU600 × 218 600 218.0 14.4 119.8 94.0 156.7 54771 2512
PU600 × 218 600 218.5 15.4 126.0 98.9 164.8 58118 2660
PU600 × 226 600 225.5 18.0 139.0 109.1 181.9 69300 3073
PU600 × 226 600 226.0 19.0 145.0 114.0 190.0 72320 3200
PU600 × 226 600 226.4 19.8 150.0 117.7 196.2 75618 3340
PU600 × 228 600 227.6 14.5 123.5 96.9 161.6 61468 2701
PU600 × 228 600 228 15.8 123.7 97.1 161.8 61560 2700
PU600 × 228 600 228.0 15.3 128.4 100.8 168.0 64375 2823
PU600 × 228 600 228.5 16.3 134.6 105.7 176.1 68010 2976
PU700 × 200 700 200 9.0 84 65.1 93 23000 1150
PU700 × 200 700 200 10.0 96.3 75.6 108 26800 1340
PU700 × 220 700 220 9.7 98.6 77.4 110.6 33770 1535
PU750 × 205a 750 204 10.0 99.2 77.9 103.8 28710 1410
PU750 × 205b 750 205.5 11.5 109.9 86.3 115.0 32850 1600
PU750 × 205c 750 206 12.0 113.4 89.0 118.7 34270 1665
PU750 × 220a 750 220.5 10.5 112.7 88.5 118.0 39300 1780
PU750 × 220b 750 222 12.0 123.4 96.9 129.2 44440 2000
PU750 × 220c 750 222.5 12.5 127.0 99.7 132.9 46180 2075
PU750 × 225a 750 223.5 13.0 130.1 102.1 136.1 50700 2270
PU750 × 225b 750 225.0 14.6 140.6 110.4 147.2 56301 2502
PU750 × 225c 750 225.5 15.0 144.2 113.2 150.9 58140 2580

PU Spundwand Es ist wichtig, dass die nachfolgenden Pfähle ausreichend mit dem vorhergehenden Pfahl verzahnt sind, bevor sie losgelassen und der Hammer eingesetzt wird. U-Profile Stahl Spundwand Dies kann durch einen vorab ausgehobenen Graben in der Mauerlinie erreicht werden, der automatisch die Rammlänge verkürzt.